language
PRODUCTS
Solid phase columns | PuriTox Total Myco-MS Solid phase columns | PuriTox Total Myco-MS Solid phase columns | PuriTox Total Myco-MS
Manufacturer: R-Biopharm
Origin: Germany
Code: TC-MT3000
Test format: 25 solid phase clean-up columns (syringe format)
 
TC-MT3000 Testing laboratories Quantity: 0 cái

Solid phase columns | PuriTox Total Myco-MS

  • Solid phase columns | PuriTox Total Myco-MS
    Manufacturer: R-Biopharm
    Origin: Germany
    Code: TC-MT3000
    Test format: 25 solid phase clean-up columns (syringe format)
     

1. Intended use

Solid phase clean-up columns for the purification of 11 mycotoxins. PuriTox Total Myco-MS® (Art. No. TC-MT3000) can be used for the simultaneous detection of aflatoxins B1, B2, G1, G2, ochratoxin A, fumonisins B1 and B2, deoxynivalenol, zearalenone, T-2 and HT-2 by LC-MS/MS.

2. General information

The columns reduce background interference therefore producing better chromatography and improving accuracy of results. The clean-up columns can be used in conjunction with LC-MS/MS for the analysis of cereal samples. The toxins are extracted from the sample, filtered and passed through the solid phase clean-up column.

* Benefits

Simultaneous detection of 11 mycotoxins in a single LC-MS/MS run.

Suitable for the analysis of ochratoxin and fumonisin, unlike some competitor products.

One sample preparation and extraction required per sample for the analysis, saving time.

* Video

3. Specifications Solid phase columns | PuriTox Total Myco-MS

Art. No TC-MT3000
Test format  25 solid phase clean-up columns (syringe format)
Sample preparation A representative sample should be obtained by following an officially recognised sampling procedure. Sample is extracted using solvent, (Extraction solvent can vary depending on the commodity analysed) filtered and passed through the solid phase extraction column.
Evaluation HPLC or LC-MS/MS.
LOD (Detection Limit) Information provided is typical LOD obtained by R-Biopharm. Please note that this is dependant on method, LC conditions and equipment used.

B1 0.05 ng/ml, B2 0.05 ng/ml,
G1 0.05 ng/ml, G2 0.05 ng/ml,
OTA 0.05 ng/ml, FB1 1 ng/ml,
FB2 1 ng/ml, DON 0.1 ng/ml,
ZON 0.05 ng/ml, T-2 0.05 ng/ml,
HT-2 0.05 ng/ml.
Detected analyte

- Aflatoxins B1, Aflatoxins B2, Aflatoxins G1, Aflatoxins G2, Ochratoxin A, Fumonisin B1, Fumonisin B2, Deoxynivalenol, Zearalenone, T-2 and HT-2. May also be suitable for the analysis of other metabolites.

- Methods are available for all matrices covered by legislation as well as additional commodities. Please contact your local R-Biopharm distributor for further information.

You did not use the site, Click here to remain logged. Timeout: 60 second