NIPPON Genetics EUROPE

FastGene NanoView Plus Photometer

FastGene NanoView Plus Photometer

High-precision microvolume & cuvette photometer

Manufacturer: Nippon Genetics Europe

  • Enhanced precision and stability due to the Xenon flash lamp
  • Fast measurement time: < 1 sec
  • Built for everyday workflows:
    • Fast measurements
    • Clear purity assessment
    • Reliable performance across a wide range of sample concentrations
  • Convenient data management

Code: FG-NP03

Product detail

FASTGENE® NANOVIEW PLUS PHOTOMETER – HIGH-PRECISION MICROVOLUME & CUVETTE PHOTOMETER

1. Product Overview - FastGene® NanoView Plus Photometer

The FastGene® NanoView Plus Photometer (Cat. No. FG-NP03) from Nippon Genetics Europe is a high-precision microvolume and cuvette photometer designed for rapid DNA, RNA, and protein quantification, as well as bacterial density measurement using OD600.

With a microvolume sample requirement of only 1–2 µL and a measurement time of less than one second, the instrument helps minimize sample consumption and streamline routine analytical workflows. Its xenon flash lamp, intuitive touchscreen interface, and integrated data management system provide convenient and efficient operation.

NanoView Plus measures absorbance at 230 nm, 260 nm, and 280 nm in microvolume mode and supports OD600 measurements using a cuvette. It is suitable for molecular biology, microbiology, and life science laboratories.

2. Key Features

2.1. Reliable Reads, Clear Decisions

The FastGene® NanoView Plus enables rapid DNA, RNA, and protein quantification, while supporting sample purity assessment and bacterial density measurement.

  • 230 nm: Helps detect UV-absorbing contaminants.
  • 260 nm: Used for nucleic acid quantification.
  • 280 nm: Supports assessment of protein content.
  • 600 nm: Measures bacterial density using the OD600 cuvette mode.

The instrument is designed for fast measurements, clear purity assessment, and reliable performance across a wide range of sample concentrations.

2.2. Clean Software, Simple Operation

NanoView Plus features an intuitive interface with easy-to-recognize icons and a logical workflow, allowing users to select measurement modes and interpret results with ease.

  • 18 built-in measurement modes.
  • 7-inch LCD touchscreen compatible with laboratory gloves.
  • Clear result presentation for easy reading and interpretation.
  • Standalone instrument design for routine laboratory workflows.

2.3. Precision Xenon Flash Lamp

The FastGene® NanoView Plus uses a xenon flash lamp as its light source, helping maintain stable measurement performance while reducing preparation time.

Key benefits include:

  • No warm-up time required.
  • Measurement time of less than one second.
  • Stable light output for reliable results.
  • Long lamp lifetime and low maintenance requirements.
  • Consistent performance over time.

2.4. Convenient Data Management

NanoView Plus incorporates an integrated file management system for convenient storage, organization, and transfer of measurement data.

  • 32 GB internal storage.
  • Folder-based data organization.
  • Direct data storage or transfer to an external USB drive.
  • Data export in Excel, CSV, text, or object file formats.
  • Flexible naming of measured values.
  • Ability to delete or replace individually selected measurement results.

These features support organized data handling and convenient result retrieval in laboratory workflows.

3. Technical Specifications

General, Optical specifications

Photometric system

Microvolume and cuvette photometer

Absorbance accuracy

3% (at 0.97A at 302 nm), 23 ± 2C°

Photometric range

0.04 – 30 A (10mm equivalent)

Spectral bandwidth

≤1.8 nm (FWHM at Hg 254 nm)

Measurement time

< 1 sec

Pathlength

0.75 mm (fixed)

Absorbance precision

SD 0.002 or 2% CV

Wavelengths

  • Microvolume: 230 nm / 260 nm / 280 nm
  • Cuvette: 600 nm (OD600)

Wavelenght accuracy

± 1 nm

Sample volume

1–2 µL (microvolume)

Light source

Xenon flash lamp

Detector

CMOS linear image sensor (2048 pixels)

Detection limit

  • dsDNA: 2.0 ng/µL
  • RNA: 1.6 ng/µL
  • BSA: 0.06 mg/mL
  • IgG: 0.03 mg/mL

Maximum concentration

  • dsDNA: 1,500 ng/µL
  • RNA: 1,200 ng/µL
  • BSA: 45 mg/mL
  • IgG: 21 mg/mL

Dimensions

216 mm x 165 mm x 290 mm

Weight

3.0 kg

Hardware, Display

CPU

Octa Core ARM® CortexTM-A53 Processor

Storage

32 GB Internal Storage

Connectivity

4 × USB ports, Ethernet, RS-232

Data export format

csv excel text

Display

7″ LCD touch display (glove compatible)

Glove compatibility

Yes

Calibration

Yes

4. Applications

The FastGene® NanoView Plus Photometer is suitable for routine analytical applications in molecular biology, microbiology, and life science laboratories, including:

  • DNA and RNA quantification: Determining nucleic acid concentrations after extraction or purification.
  • Nucleic acid purity assessment: Measuring absorbance at 230, 260, and 280 nm to support sample quality assessment.
  • Protein quantification: Measuring UV absorbance of protein samples compatible with the instrument's measurement modes.
  • Bacterial density monitoring: Measuring OD600 using a cuvette in microbiology and bacterial culture workflows.
  • Pre-PCR/qPCR sample assessment: Supporting DNA/RNA concentration and purity checks before downstream analysis.

5. Benefits of FastGene® NanoView Plus

The FastGene® NanoView Plus combines microvolume measurement, cuvette-based analysis, and data management in a compact instrument. Low sample consumption, rapid measurements, a stable xenon light source, and a user-friendly interface help streamline routine laboratory workflows.

It is a suitable solution for laboratories requiring DNA, RNA, and protein quantification alongside OD600 monitoring in one instrument, with an emphasis on measurement speed and convenient data management.

6. Contact Us for Technical Support and Quotation

Looking for a solution for DNA/RNA quantification, nucleic acid purity assessment, or OD600 bacterial density monitoring? Contact Pacificlab for technical information and a quotation for the FastGene® NanoView Plus Photometer to identify a solution that fits your laboratory requirements.

Pacificlab – Official Distributor of Nippon Genetics Europe in Vietnam

☎️ 0989 092 258
📩 Sales@pacificlab.vn
🌏 www.pacificlab.vn

Video

  • FastGene NanoView Plus | 2-in-1 Microvolume & OD600 Photometer

Similar products

NIPPON Genetics EUROPEFastGene NanoSpec Spectrophotometer

Code: FG-NP01